PM862K01工控AC800M系统主单元控制器输入输出
PM862K01工控AC800M系统主单元控制器输入输出
产品价格:¥9844.00(人民币)
  • 规格:完善
  • 发货地:福建厦门
  • 品牌:
  • 最小起订量:1
  • 免费会员
    会员级别:试用会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:厦门雄霸电子商务有限公司

    联系人:(先生)

    联系手机:

    固定电话:

    企业邮箱:2235954483@qq.com

    联系地址:

    邮编:

    联系我时,请说是在新塑胶网上看到的,谢谢!

    商品详情
      产品参数
      品牌PM862K01
      输出频率350kHz
      物料编码87540
      颜色白色
      是否进口
      加工定制
      工作电压220V
      产品认证54100
      名称励磁系统
      系列3BHE035301R1002
      使用环境常温常压
      功率1200
      质保一年
      销售范围中国
      可售卖地全国
      型号PM862K01

      Honeywell Analytics System 57 Controller, previously by?Zellweger and Sieger.

      Now obsolete, spares are no longer ailable. A new system controller is needed, the choice will depend on system size and the number of channels required. There are three models for small scale systems;??Unipoint,?Touchpoint Plus, and?19″ rack version.?For larger systems, the?Touchpoint Pro?controller will be suitable.

      System 57 was the product of 50 years of experience in gas detection. The controller had the?flexibility to accept inputs from combustible, toxic and oxygen gas detectors, flame, heat and smoke detectors, plus manual call points.

      Designed as a modular system, the capability could be expanded and customised with system control and alarm properties uniquely defined for a users application. Comprising of control cards, interface cards that link the various fire and gas detectors to the control cards.? The engineering card was used for commissioning, maintenance, system health check and alarm level auditing.

      Controller cards

      Fire and gas control cards can be inserted in the same rack.

      5701? gas control card is for single-channel operation, and four-channel operation is possible with the 5704 gas control card.? Each card has two inputs 4-20mA and mV for?catalytic detection. Gas readings are displayed and can be viewed in graphical format. Peak readings and sensor performance monitored too. Viewing modes can be changed between single or combination channels. Three levels of alarm?and options of individual, zoned, voted, master, time-delayed, update and rate of rise alarm facilities.

      5704F Fire Control Card has four fire zone inputs, suitable for pairing with flame, smoke, heat detectors?and manual call points. LEDs indicate individual fire zone status. Each card has two lines monitored outputs for alarm, 15 cards possible in a 19-inch rack giving 60 fire zones.

      Interface cards

      There are nine versions of interface card ailable (5 for 5701 Gas, 2 for 5704 Gas and 2 for 5704 Fire Control Cards) accepting under 2.5mm 14 gauge cable. Each has relay options and individual control card power option.

      Serial communications

      A serial communications module is ailable allowing pairing with a remote device (DCS, PLC or SCADA package) allowing channel monitoring, checking and configuration.
      ?? MODBUS RTU protocol
      ? Digital RS485 / 422 / 232 standard
      ? Bi-directional
      ? Electrically isolated communications bus
      ? SCADA graphics package option

      Installation

      System 57 racking units come in three-unit high versions, length 19 inch 16 way or half-length eight way—rear access, front access option for eight-way version. Cabinets are ailable that can be wall-mounted for both versions.

      Spares

      ?

      05701-A-0309 Master Alarm Update Module Kit
      05701-A-0312 Modbus Interface Module Kit-RS 485/RS 422
      05701-A-0313 Modbus Interface Module Kit-RS 232
      05701-A-0314 Event Print Module Kit-RS 232
      05701-A-0339 Master Alarm Update Panel
      05704-A-0148 5704F Fire Status Panel

      Racks and Cabinets

      05701-A-0452 Cabinet – Wall Mounting – 8 Way
      05701-A-0451 Cabinet – Wall Mounting – 16 Way
      05701-A-0506 Sub rack – Front Access – 8 Way
      05701-A-0516 Sub rack – Rear Access – 8 Way
      05701-A-0505 Sub rack – Front Access – 16 Way
      05701-A-0515 Sub rack – Rear Access – 16 Way
      05701-A-0365 Blanking Panel – Card Slot
      05701-C-0471 Blanking Panel – 1U X 19″ (16 Way)
      05701-C-0474 Blanking Panel – 1U X ? 19″ (8 Way)

      Power Supplies

      05701-A-0405 Power Supply Unit- AC To DC-16 Way- 50 Watts
      05701-A-0406 Power Supply Unit- AC To DC-8 Way- 50 Watts
      05701-A-0440 Power Supply Module- 50 W (Upgrade For PSU & Sub Units)
      05701-A-0441 Power Supply Subunit- 50 Watts (Upgrade For 16 Way PSU)

      5701 Spares

      05701-A-0550 System 57 Calibration Plug
      05701-A-0361 Engineering Card
      05701-A-0325 DC Input Card
      05701-A-0301 Single Channel Control Card – 4-20mA
      05701-A-0302 Single Channel Control Card- Catalytic
      05701-A-0351 Control Card- Single Channel- 5701
      05701-A-0283 Sensor Drive Module – 4-20mA- 5701
      05701-A-0284 Sensor Drive Module- Catalytic- 5701
      05701-A-0285 Analogue Output Module- 5701
      05701-A-0326 Field Interface Card (No Relays – Sensor Input Only)
      05701-A-0327 Relay Card-Double SPCO- 5701 (A1, A2 & Fault Single Pole Changeover Relays)
      05701-A-0328 Relay Card-Triple SPCO-5701 (A1, A2, A3 Fault & Inhibit Single Pole Changeover Relays)
      05701-A-0329 Relay Card- Triple DPCO- 5701 (2xA1, 2xA2, 2xA3 Fault & Inhibit Single Pole Changeover Relays)
      05701-A-0330 High Integrity Relay Card-Double SPCO -5701 (2xA1, 2xA2, 2xA3 Fault & Inhibit Single Pole Changeover Relays)
      05701-C-0390 Interconnection Cable- 5701
      05701-C-0127 Model 5701 Scale Label – Catalytic – 0-20 LEL
      05701-C-0130 Model 5701 Scale Label – Catalytic – 0- LEL
      05701-C-0131 Model 5701 Scale Label – mA – 0- LEL
      05701-C-0135 Model 5701 Scale Label – Catalytic – 0-4 V/V
      05701-C-0137 Model 5701 Scale Label – mA – 0-25 V/V
      05701-C-0138 Model 5701 Scale Label – mA – 0-30 V/V
      05701-C-0139 Model 5701 Scale Label – mA – 0- V/V
      05701-C-0141 Model 5701 Scale Label – mA – 0-10 V/V
      05701-C-0145 Model 5701 Scale Label – mA – 0-5ppm
      05701-C-0146 Model 5701 Scale Label – mA – 0-10ppm
      05701-C

    0571-87774297